Home>ISO Standards>ISO 9464:2008 pdf free

ISO 9464:2008 pdf free

ISO 9464:2008 pdf free.Guidelines for the use of ISO 5167:2003
The objective of this Technical Report is to provide guidance on the use of ISO 5167:2003 (all parts).
ISO 5167:2003 is an International Standard for flow measurement based on the differential pressure generated by a constriction introduced into a circular conduit (see Iso 5167-1:2003, 5.1). It presents a set of rules and requirements based on theory and experimental work undertaken in the field of flow measurement.
For a more detailed description of the scope, reference should be made to ISO 5167-1:2003, Clause 1.
Definitions and symbols applicable to this Technical Report are given in ISO 5167-1:2003, Clauses 3 and 4.
Neither ISO 5167-1:2003 nor this Technical Report give detailed theoretical background, for which reference should be made to any general textbook on fluid flow.
With the application of the rules and requirements set out in ISO 5167-1:2003, it is practicable to achieve flow measurement within an uncertainty of approximately 1 % of the calculated flowrate. The constraints applicable to each of the primary devices described in ISO 5167:2003 (parts2 to 4) need to be given consideration before determining the most suitable type for a particular application. Parts 2 to 4 can also be used to form the basis for preliminary design of a metering system.
The information necessary for detailed design, manufacture and final check is specified in the clauses and paragraphs of ISO 5167:2003 (parts 2 to 4).
Secondary instrumentation is not covered by ISO 5167-1:2003, but Clause 6 of this Technical Report makes normative reference to ISO 2186.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 2186, Fluid flow in closed conduits一Connections for pressure signal transmissions between primary and secondary elements
ISO/TR 3313:1998,Measurement of fluid flow in closed conduits 一Guidelines on the effects of flow pulsations on flow -measurement instruments
ISO 4006, Measurement of fluid flow in closed conduits一Vocabulary and symbols
ISO 5167-1:2003, Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full 一Part 1: General principles and requirements
ISO 5167-2:2003, Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full- Part 2: Orifice plates.ISO 9464 pdf download.

Related standards