Home>ISO Standards>ISO 3008-2:2014 pdf free

ISO 3008-2:2014 pdf free

ISO 3008-2:2014 pdf free.Fire-resistance tests – Lift landing door assemblies
This part of ISO 3008 specifies the method of the test for determining the fire resistance of the lift landing door assemblies which can be exposed to fire from the landing side. The procedure applies to all the types of lift landing door assemblies used as a means of access to the lifts in buildings and which are intended to provide a fire barrier to the spread of fire via the lift well.
The procedure allows for the measurement of integrity and, if required, the measurement of radiation and thermal insulation.
No requirements other than the verification that the specimen is operational are included for the mechanical conditioning before the test.
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 834-1, Fire-resistance tests一Elements of building construction一Part 1: General requirements
ISO 834-4, Fire-resistance tests一Elements of building construction 一Part 4: Specific requirements for loadbearing vertical separating elements
ISO 834-8, Fire-resistance tests一Elements of building construction一Part 8: Specific requirements for non-loadbearing vertical separating elements
ISO 3008-1, Fire-resistance test一Part 1一Door and shutter assemblies
ISO 5167-1, Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full一Part 1: General principles and requirements
ISO 5221,Air distribution and air dffusion一Rules to methods of measuring airflow rate in an air handling duct
complete assembly, including any frame or guide, door leaf or leaves, which is provided for access to and from the lift and the landing and includes all panels, hardware, sealing materials, and any operating components
form of construction used to close off the furnace and to support the door assembly being evaluated and which has a quantifiable influence on both the thermal heat transfer between the construction and the test specimen and provides known resistance to thermal distortion total flow of hot gases passing through the openings and gaps of the door assembly due to overpressure on the landing side.ISO 3008-2 pdf free download.

Related standards