ISO 19095-1:2015 pdf free.Plastics一Evaluation of the adhesion interface performance in plastic-metal assemblies
This part of ISO 19095 specifies the evaluation methods for the adhesion interface performance in plastic-metal assemblies.
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 291, Plastics一Standard atmospheres for conditioning and testing
ISO 472, Plastics一Vocabulary
ISO 3530, Vacuum technology一Mass -spectrometer-type leak-detector calibration
ISO 19095-2, Plastics 一Evaluation of the adhesion interface performance in plastic-metal assemblies一Part 2: Test specimens
ISO 19095-3, Plastics 一Evaluation of the adhesion interface performance in plastic-metal assemblies一Part 3: Test methods
ISO 19095-4, Plastics一Evaluation of the adhesion interface performance in plastic-metal assemblies一Part 4: Environmental condition for durability
IEC 60068-2-11, Basic environmental testing procedures一Part 2-11: Tests一Test Ka: Salt mist
IEC 60068-2- 67, Environmental testing一Part 2-67: Tests一Test Cy: Damp heat, steady state, accelerated test primarily intended for components
For the purposes of this document, the terms and definitions given in ISO 472 and the fllowing apply.
The fllowing are used as the accssory for helium leak testing:
a) helium gas cylinder for supplying the tracer gas;
b) compressor and pressure reducing valve;
c) various kinds of joint and piping for assembling of vacuum system and pressurizing system;
d) pressure gauge for measurement of the pressure of test specimen;
e) vacuum gauge for measurement of the pressure of test specimen.
Two separate chambers or one chamber with rapid change of temperature may be used. If two chambers are used, one for the low temperature and the other for the high temperature, the location shall be such as to allow transfer of the specimen from one chamber to the other within the prescribed time. Either manual or automatic transfer methods may be used.
The chambers shall be capable of maintaining the atmosphere at the appropriate temperature for the test in any region where the specimen is placed.
After insertion of the test specimens, the air temperature shall be within the specified tolerance after a time of not more than 10 % of the exposure time.ISO 19095-1 pdf download.