Home>ISO Standards>ISO 10762:2015 pdf free

ISO 10762:2015 pdf free

ISO 10762:2015 pdf free.Hydraulic fluid power – Mounting dimensions for cylinders, 10 MPa (100 bar) series
ISO 10762 establishes mounting dimensions for cylinders for use at 10 MPa [100 bar1], as required for interchangeability of these cylinders.
NOTE ISO 10762 allows manufacturers of hydraulic equipment flexibility in the design of 10 MPa (100 bar) cylinders and does not restrict technical development; however, it does provide basic guidelines.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 273, Fasteners一Clearance holes for bolts and screws
ISO 1179-1, Connections for general use and fluid power一Ports and stud ends with ISO 228-1 threads with elastomeric or metal-to-metal sealing一Part 1: Threaded ports
ISO 3320, Fluid power systems and components一Cylinder bores and piston rod diameters and area ratios一Metric series
ISO 4395, Fluid power systems and components一Cylinder piston rod end types and dimensions
ISO 5598, Fluid power systems and components一Vocabulary
ISO 6099, Fluid power systems and components一Cylinders一ldentification code for mounting dimensions and mounting types
ISO 6149-1, Connections for hydraulic fluid power and general use一Ports and stud ends with ISO 261 metric threads and 0-ring sealing一Part 1: Ports with truncated housing for O-ring seal
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 5598 apply.
4 Dimensions
Mounting dimensions for cylinders manufactured in accordance with this International Standard shall be as given in Figures 1 to 13 and Tables 1 to 13.
7 Mounting types
ISO 10762 includes the following mounting types, in accordance with ISO 6099:
一ME5一Rectangular flange, integral with head (see Figure 3 and Table 3);
一ME6一Cap, rectangular flange (see Figure 4 and Table 4);
一MP1一Cap, fixed clevis (see Figure 5 and Table 5);
一MP3一Cap, fixed eye (see Figure 6 and Table 6);
一MP5一Cap, fixed eye with spherical plain bearing (see Figure 7 and Table 7);
一MS2一Side lugs (see Figure 8 and Table 8);
一MT1一Head, integral trunnion (male; see Figure 9 and Table 9);
一MT4一Intermediate trunnion (male) with selectable position (see Figure 10 and Table 10);
一MX1一Both ends, studs or tie rods extended (see Figure 11 and Table 11);ISO 10762 pdf download.