AS NZS 60335.2.58:2018 pdf free.Household and similar electrical appliances – Safety
Appliances with type X attachment, except those having a specially prepared cord, are fitted with the lightest permissible type of flexible cable or cord of the smallest cross-sectional area specified in Table 13, and other appliances are tested as delivered.
Appliances intended to be filled with water by the user are completely filled with the spillage solution. A further quantity of the solution, equalto 5 % of the capacity of the appliance or 10 I, whichever is the greater, is then poured in steadily over a period of 1 min.
Other appliances are operated through one complete cycle of normal operation, after which the timer switch, float or pressure-operated switch is made inoperative, and 5 g of the standard detergent given in IEC 60436 is added per litre of water in the appliance at the highest level of fill during normal operation and the appliance is operated in the intended manner.
For appliances, the tops of which are intended to form working surfaces, a quantity of 0,2 1 of the spillage solution is poured steadily from a height of about 50 mm on to the middle of the top of the appliance for a period of 15 s.
Immediately after this test, the appliance shall withstand the electric strength test as specified in 16.3 and inspection shall show that there is no trace of water on insulation that could result in a reduction of clearances or creepage distances below the values specified in Clause 29.
Appliances that are provided with a tap intended for filling or cleaning shall be constructed so that the water from the tap cannot come into contact with live parts.Compliance is checked by the following test.
The tap is fully opened for 1 min with the appliance connected to a water supply having the maximum water pressure indicated. Tiltable and movable parts, including lids, are tilted or placed in the most unfavourable positions. Swivelling outlets of water taps are so positioned as to direct water on to those parts that will give the most unfavourable result. Immediately following this treatment, the appliance shall withstand the electric strength test of 16.3.AS NZS 60335.2.58 pdf download.